AMMRL: position announcement

From: Morton, Martha <martha.morton_at_uconn.edu>
Date: Fri, 14 Sep 2007 12:19:38 -0400

FACILITY SCIENTIST (Academic Assistant II/III)

BIOMOLECULAR NMR SPECTROSCOPIST

 

 University of Connecticut

Biotechnology/Bioservices Center

 

The NMR Facility of the Biotechnology/Bioservices Center, University of Connecticut, is looking for an outstanding scientist to support its Biomolecular NMR research program. Faculty research interests include: membrane proteins, amyloidogenic proteins, protein folding intermediates, neuromuscular junction proteins, and protein-nucleic acid interactions. Current instrumentation in the Facility specifically available for solution Biomolecular NMR includes a 500 MHz Bruker Avance and a 600 MHz Varian Inova with a cryogenic probe. The NMR Facility will serve the University community along with the interdisciplinary UConn Partnership for Excellence in Structural Biology, which includes NMR colleagues at our Health Center sister campus, where a new 800 MHz instrument will be housed.

Responsibilities for this position include ensuring the smooth and reliable operation of NMR machines; participation in NMR methods development; implementing new NMR experiments; training of students; and participation in writing instrument grants; thus enabling faculty research.

 

Minimum Qualifications: To be considered for an Academic Assistant II, candidates must have a Master's degree with demonstrated experience. For consideration as an Academic Assistant III, candidates must have a Ph.D. or a Master's degree with significant experience. For either level the candidate should be strongly motivated; be able to work and communicate effectively, orally and in writing, with colleagues; be able to troubleshoot problems independently; keep abreast of new developments in NMR; and have demonstrated experience in multi-dimensional heteronuclear solution NMR (particularly protein NMR).

 

Preferred Qualifications: We are interested primarily in candidates with expertise with Varian NMR machines, although additional familiarity with Bruker instruments is a plus. The candidate should be competent with Unix/Linux operating systems, with software for NMR data analysis (NMRPipe, Felix, Sparky) and with software for NMR structure determination (X-Plor, CYANA).

 

This is a full-time, 11-month appointment subject to renewal to assist the further development of the Biomolecular area of the NMR Facility. Renewal is contingent upon the availability of funding.

 

Candidates should send a cover letter, curriculum vitae, and three letters of professional references to: Sue Levesque, University of Connecticut, Biotechnology/Bioservices Center, 91 N. Eagleville Rd., Unit 3149, Storrs, CT 06269-3149. Review of applications will begin October 1, and continue until the position is filled.

 

The University of Connecticut encourages applications from under-represented groups, including minorities, women, and people with disabilities.

 
Martha Morton, Ph. D.
University of Connecticut NMR Facility Scientist
Chemistry NMR Lab Director
(860)486-4069
Received on Fri Sep 14 2007 - 12:44:23 MST

This archive was generated by hypermail 2.4.0 : Sun Jun 11 2023 - 16:33:28 MST