Re: [AMMRL] Bruker SampleCase Reliability #Bruker

From: Jessica Bach via groups.io <jessie.bach=milliporesigma.com_at_groups.io>
Date: Fri, 9 Jun 2023 16:34:48 +0000

We have not had problems with the 60 position sample case.


Jessie Bach



________________________________
> From: main_at_ammrl.groups.io <main_at_ammrl.groups.io> on behalf of vbegue via groups.io <vbegue=eastman.com_at_groups.io>
> Sent: Friday, June 9, 2023 7:31 AM
> To: main_at_ammrl.groups.io <main_at_ammrl.groups.io>
> Subject: [AMMRL] Bruker SampleCase Reliability #Bruker

All,

I'm wondering if anyone can make any comments about the reliability of the
Bruker SampleCase with 45 slots vs 60 slots. We have both configurations in
our lab and the 60 slot model is having problems with jamming as it moves
between the concentric circles. The 45 slot model only has one ring and does
not encounter this problem. I'm wondering if the jamming issues I'm seeing in
the 60 slot model are just sort of an inherent 'feature' of the increased
alignment requirements generated by the concentric ring design or if I've
just had bad luck with the 60 slot model and other people are finding them
generally reliable.

Thanks,
Victoria Begue


This message and any attachment are confidential and may be privileged or
otherwise protected from disclosure. If you are not the intended recipient,
you must not copy this message or attachment or disclose the contents to
any other person. If you have received this transmission in error, please
notify the sender immediately and delete the message and any attachment from
your system. Merck KGaA, Darmstadt, Germany and any of its subsidiaries do
not accept liability for any omissions or errors in this message which may
arise as a result of E-Mail-transmission or for damages resulting from any
unauthorized changes of the content of this message and any attachment there
to. Merck KGaA, Darmstadt, Germany and any of its subsidiaries do not guarantee
that this message is free of viruses and does not accept liability for any
damages caused by any virus transmitted therewith.



-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#193): https://urldefense.com/v3/__https://ammrl.groups.=
io/g/main/message/193__;!!PvDODwlR4mBZyAb0!W3ZBMg66mfbtfty8UMTVxqLO6B_7Keq2=
kraT9MzNqwngLgIKV7OyGNYqYrWqqo9RjB889L_xKUZTt5J_Zmvdnfnib7ZU$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/99427463/=
7559972__;!!PvDODwlR4mBZyAb0!W3ZBMg66mfbtfty8UMTVxqLO6B_7Keq2kraT9MzNqwngLg=
IKV7OyGNYqYrWqqo9RjB889L_xKUZTt5J_ZmvdnSHfRv1b$
Mute #bruker:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/mut=
ehashtag/bruker__;!!PvDODwlR4mBZyAb0!W3ZBMg66mfbtfty8UMTVxqLO6B_7Keq2kraT9M=
zNqwngLgIKV7OyGNYqYrWqqo9RjB889L_xKUZTt5J_ZmvdnRdPGaBU$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Fri Jun 09 2023 - 09:53:11 MST

This archive was generated by hypermail 2.4.0 : Wed Oct 25 2023 - 14:42:24 MST