Can you do “edc” in the command line? I know that works in Topspin 4.0.8
version that I run.

Best,
Matt
--
Matthew J. Nethercott, Ph.D.
Matthew.Nethercott_at_gmail.com<mailto:Matthew.Nethercott_at_gmail.com>

> From: "main_at_ammrl.groups.io" on behalf of Bob Berno <bberno_at_mcmaster.ca>
> Date: Thursday, September 14, 2023 at 11:40 AM
> To: "main_at_ammrl.groups.io" <main_at_ammrl.groups.io>
> Subject: Re: [AMMRL] Creating new experiment in TopSpin command line #Bruker

Hello Ann,

You could type the command: iexpno

As the name implies, it "increments" the experiment number, while taking all
of the parameters from the current dataset.

If the next dataset already exists, then you simply move to the new dataset=
(nothing is overwritten). But if it doesn't exist, then a new dataset is
created with all of the current parameters but no data.

I am too lazy to type "iexpno" so I wrote a one line macro called: i
The macro calls "iexpno"

Cheers,
Bob.
On 2023-09-14 1:05 p.m., Anne Carroll via groups.io wrote:


Hello,

Is there a way to create a new EXPNO from the TopSpin command line, avoiding
the interactive NEW experiment window?

I would like to be able to create a new EXPNO in the current dataset with the
current parameters as part of a chain of TopSpin commands.

Thank you,
Anne Carroll
--
Anne M. Carroll, Ph.D. (she/her) NMR/MS Instrumentation Specialist Department
of Chemistry and Biochemistry Miami University Oxford, Ohio USA 513-529-3163
Office 678-637-6739 Cell carrol50_at_miamioh.edu<mailto:carrol50_at_miamioh.edu>

-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#580): https://urldefense.com/v3/__https://ammrl.groups.=
io/g/main/message/580__;!!PvDODwlR4mBZyAb0!Ue1fGfb46As0MwATnMsDuefhPldLEhXc=
WSFHLeXLdnQuuYaLWsu6rPzj3MNQG4ykv3IPu15msy4Vh5dzlsLFDGNkZg$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/101363004=
/7559972__;!!PvDODwlR4mBZyAb0!Ue1fGfb46As0MwATnMsDuefhPldLEhXcWSFHLeXLdnQuu=
YaLWsu6rPzj3MNQG4ykv3IPu15msy4Vh5dzlsJ8OKNh2w$
Mute #bruker:https://urldefense.com/v3/__https://ammrl.groups.io/g/main/mut=
ehashtag/bruker__;!!PvDODwlR4mBZyAb0!Ue1fGfb46As0MwATnMsDuefhPldLEhXcWSFHLe=
XLdnQuuYaLWsu6rPzj3MNQG4ykv3IPu15msy4Vh5dzlsK5IdQMCQ$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Thu Sep 14 2023 - 10:46:22 MST

This archive was generated by hypermail 2.4.0 : Wed Oct 25 2023 - 14:44:18 MST