AMMRL: Topspin to vnmr1?

From: <Elizabeth.F.McCord_at_dupont.com>
Date: Tue, 23 Sep 2014 10:11:18 +0000

Does any one know a procedure to import new Topspin Bruker data into vnmr1?
From: Richard Shoemaker [mailto:richard.shoemaker_at_Colorado.EDU]
Sent: Friday, September 19, 2014 8:06 PM
To: ammrl_at_ammrl.org
Subject: AMMRL: Extended Tuning Kit for late 1990s Varian NB-CPMAS Probe anyone? - FOUND

Dear All:

Let me sing another verse to an old song about our amazing professional community! So many people responded to my request, looking through their old, abandoned parts and pieces, sending photos, ...etc. I know how busy our jobs can be, so to each and every one of you who responded in any way to my request for these tuning-range sticks for early 1990s Varian CPMAS (NB) probes, I can only say THANK YOU!

Brian Cherry at Arizona State had a similar probe, and came through with flying colors. I now have enough sticks to keep one for each nucleus after finding the correct capacitance or inductance, so I no longer have to keep de-soldering and re-soldering components to change nuclei.

Thanks again to everyone.

Sincerely,

-Rich Shoemaker
---
Richard K. Shoemaker, Ph.D.,
Research Professor & Director, NMR Spectroscopy Facility
University of Colorado at Boulder
Phone:  (303) 492-7062  Fax: (303) 492-5894
E-Mail: Richard.Shoemaker_at_Colorado.edu<mailto:Richard.Shoemaker_at_Colorado.edu>
Web: http://chemnmr.colorado.edu/rshoe
This communication is for use by the intended recipient and contains
information that may be Privileged, confidential or copyrighted under
applicable law. If you are not the intended recipient, you are hereby
formally notified that any use, copying or distribution of this e-mail,
in whole or in part, is strictly prohibited. Please notify the sender by
return e-mail and delete this e-mail from your system. Unless explicitly
and conspicuously designated as "E-Contract Intended", this e-mail does
not constitute a contract offer, a contract amendment, or an acceptance
of a contract offer. This e-mail does not constitute a consent to the
use of sender's contact information for direct marketing purposes or for
transfers of data to third parties.
The dupont.com http://dupont.com web address may be used for a limited period of time by the following
divested businesses that are no longer affiliated in any way with DuPont:
Axalta Coating Systems
Borealis Polymers NV
Jacob Holm & Sonner Holding A/S (Jacob Holm)
Kuraray Co., Ltd
Laticrete International, Inc.
DuPont accepts no liability or responsibility for the content or use of communications
sent or received on behalf of such divested businesses or for the consequences of
any actions taken on the basis of such communications.
Francais Deutsch Italiano  Espanol  Portugues  Japanese  Chinese  Korean
          http://www.DuPont.com/corp/email_disclaimer.html
Received on Tue Sep 23 2014 - 00:11:32 MST

This archive was generated by hypermail 2.4.0 : Sun Jun 18 2023 - 18:05:09 MST