Position Title: Scholar/Scientist (CHM), Solid State Nuclear
Magnetic Resonance (NMR) Spectroscopist
Position No: 80624
Location: Tallahassee, FL
Full/Part Time: Full-Time
Regular/Temporary: Temporary (2nd year renewable)
Department: Chemistry and Biochemistry
Salary Range: $50,000 to negotiable
Qualifications: Ph.D. in chemistry with specialized training and
experience in solid state NMR spectroscopy.
Requirements:
Knowledge of the terminology, principles and techniques of state of
the art Nuclear Magnetic Resonance (NMR) spectroscopy, including
solid state NMR.
Skill in the use, maintenance, and operation of modern solution and
solid state NMR spectrometers.
Familiarity with NMR data processing software.
Knowledge of and experience with standard solid state pulse sequences.
Ability to implement new solid state pulse sequences.
Ability to identify NMR experiments to solve problems in solid state chemistry.
Ability to establish and maintain effective working relationships
with faculty in Chemistry & Biochemistry and other departments.
Ability to communicate effectively both verbally and in writing.
Schedule: Regular work hours are from 8AM-5PM, although the nature
of some experiments may require to work after hours or on weekends as
necessary.
Responsibilities:
Determine in consultation with faculty and students most effective
NMR experiments and define experimental parameters for obtaining high
resolution NMR data on a variety of solid materials; communicate
results and consult with users regarding further experimentation as
necessary. (25%)
Configure solid state NMR spectrometer(s), including rf-pulse
sequences for optimum performance; perform routine maintenance on NMR
spectrometers including regularly-scheduled cryogen maintenance. (25%)
Train and mentor graduate students and post doctoral associates in
the use and applications of modern solid state NMR; supervise and
monitor bi-weekly scheduling of time on instrument(s); prepare and
deliver periodic lectures on emerging solid state NMR topics. (25%)
Collaborate with Faculty on ssNMR experiments. (25%)
Pay Plan: Contracts & Grants
How to Apply: If qualified and interested in a specific vacancy as
advertised, apply to Florida State University at
https://jobs.fsu.edu.
Applicants are required to complete the online application with all
applicable information. Applications must include work history and
all education details (if applicable) even if attaching a resume. In
addition, all applicants are required to submit a Curriculum Vita
(CV) and three letters of recommendation.
Equal Employment Opportunity: An Equal Opportunity/Access/Affirmative
Action Employer
--
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
Received on Fri Sep 03 2010 - 05:00:42 MST