ammrl: probes available from DuPont

From: SCHOLZ, THOMAS <Thomas.H.Scholz_at_dupont.com>
Date: Fri, 16 Mar 2018 21:54:44 +0000

NMR colleagues,
Over the last two years a number of older NMR systems have been shut down and disposed of here at DuPont. We have a good number of probes that we'd rather not throw in the electronic waste but we are not permitted to simply give them to someone. They must be put up for auction through DuPont's investment recovery system. For most of the probes, not all, I have informed investment recovery that the people who might be interested in these probes will not be able to afford to pay much for them. So if you are interested in any of the probes or accessories listed below don't hesitate to make some bid for it; think of it as a yard sale. To make a bid you need to go to www.investmentrecovery.dupont.com<http://www.investmentrecovery.dupont.com> and search for NMR probe. All of the probes were functional when last used but it's been quite a while since some of them have been used. The cryoprobe was taken down and stored in May of 2017 and at that time it was giving very nice spectra, especially 2D 1H{15N} and 1H{13C}. Only a few pictures were taken of these probes so there are not many pictures posted on the DuPont web site.

500 MHz Agilent HCN Cryoprobe, Cryo-platform & Helium Compressor
The probe was removed from the magnet by an Agilent service engineer and crated before I had a chance to record its model number and take a picture of it.
The Cryoplatform is a 7710 CS with serial number MRY0022862 and the Helium compressor is a water-cooled F-50L Sumitomo, serial number 4A112091C.
Also included with this cryoprobe are 24 salt-tolerant cryo-spinners (12 X 5mm + 12 X 3mm).

400 MHz Varian/Agilent Probes (45mm od) for 51mm Bore Magnet
Description

Part Number

5mm 1H {X} Z-grad pins on top

SP40P54P01





5mm 1H {X} Z-grad pins on top

SP40P54P05





5mm 1H {X} XYZ gradients

CPN04P0051





5mm 1H/19F {X} Z-grad

190803700





5mm 4Nuc H/F {C,P} PFG built in 2015,
low F19 background
See photo for special vt connection

SN40P5VP32





5mm 4Nuc C,P {H/F} Z-grad

19058300





5mm 4Nuc Switchable C,P,X {H/F} Z-grad
vt range -100 to +150C

SN40PSAN04





5mm 1H-19F No PFG

957867-00





5mm BB Switchable 13C, 31P-29Si-15N
low B11 background

190506902





10mm BB

190224400





10mm BB

SW40P16N06





8mm 1H {13C,15N} Z-grad pins on top

SW40P83P01





Nano Probe 1H {13C} Z-grad

SN40P47P02





Upper Barrel for 400 MHz Magnet















































500 MHz Varian Solid State Probes & Accessories
Description

Part Number

6.5mm CP/MAS HX

SN50P68N01





3.2mm HXY Bio-MAS
X: 79Br - 31P Y: 15N - 23Na

199055000





Varian Automated MAS Controller

M806628000





Narrowbore Solids VT Upper Stack

M806789000

















500 MHz Bruker Probes for 51mm Bore Magnet
Description

Part Number

5mm BBI Z-grad

Z8107





5mm QNP Z-grad 13C,31P,19F {1H}

Z8420





5mm QNP Z-grad 13C,31P,19F {1H}

Z8420





10mm QNP 13C,31P,29Si {1H}

Z5745





8mm 1H-19F

Z8464





2.5mm 1H {13C,15N} Z-grad

Z8433



Thomas Scholz
Email: thomas.h.scholz_at_dupont.com<mailto:thomas.h.scholz_at_dupont.com>
Office: E500/1206C
           302-695-3162


This communication is for use by the intended recipient and contains information that may be Privileged, confidential or copyrighted under applicable law. If you are not the intended recipient, you are hereby formally notified that any use, copying or distribution of this e-mail,in whole or in part, is strictly prohibited. Please notify the sender by return e-mail and delete this e-mail from your system. Unless explicitly and conspicuously designated as "E-Contract Intended", this e-mail does not constitute a contract offer, a contract amendment, or an acceptance of a contract offer. This e-mail does not constitute a consent to the use of sender's contact information for direct marketing purposes or for transfers of data to third parties.


Francais Deutsch Italiano Espanol Portugues Japanese Chinese Korean

http://www.DuPont.com/corp/email_disclaimer.html
Received on Fri Mar 16 2018 - 11:54:51 MST

This archive was generated by hypermail 2.4.0 : Tue Jun 20 2023 - 16:15:46 MST