Dear Markus and All,
Exploring new opportunities is undoubtedly exciting. Nevertheless, when
considering an investment in the NMR system, especially within the
financial constraints of our university setting, it entails a substantial
commitment. Consequently, I'm not only navigating this decision cautiously
but also working diligently to persuade our faculties of its merits. I'm
looking for insights into the technology and the advantages of Q-NMR to
better understand its potential benefits, especially in terms of long-term
quality, service, and the availability of replacement parts. I would
greatly appreciate it if you could share your thoughts on this matter.
Best regards,
Jennifer
On Wed, Sep 20, 2023 at 8:02 AM Markus <markus.enders_at_uni-heidelberg.de>
wrote:
> Dear all,
>
> has anyone purchased an NMR spectrometer of Quad Systems (https://quadsystems.tech/)
> and what is the experience? We are intersted
> in a standard 400 MHz system (i.e. 2 channels, room temperature Braodband
> probe, sample changer).
> Can anyone comment on the quality of the following components in
> comparison to a new Bruker System:
> a) Console
> b) Probes
> c) Sample Changer
> d) Software
> e) Software for automation
> f) use of Bruker pulse programs
>
> For those who wish to answer: please let me know if I should keep your
> answer confidential.
>
> Best wishes
>
> Markus
>
>
>
--
*Jennifer Sun*
Senior Research Scholar , Molecular Education, Technology and Research Innovation Center
Joint Research Assistant Professor, Department of Chemistry
North Carolina State University
2620 Yarbrough Drive
Raleigh, NC 27607
(919) 515-1160
*xsun9_at_ncsu.edu <xsun9_at_ncsu.edu>*
https://research.ncsu.edu/metric/
https://labs.ncsu.edu/
Please citing METRIC to support us:
All NMR measurements were made in the Molecular Education, Technology and
Research Innovation Center (METRIC) at NC State University.
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#615): https://urldefense.com/v3/__https://ammrl.groups.=
io/g/main/message/615__;!!PvDODwlR4mBZyAb0!RkeiFq1Td-MlHiqQYWTZUM-qVRkSJeT0=
OQDL60rGQf6rrc2AQbM99MEaVL4l-nk95sej3Lv98tvhstKVfs5yQUlSug$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/101476712=
/7559972__;!!PvDODwlR4mBZyAb0!RkeiFq1Td-MlHiqQYWTZUM-qVRkSJeT0OQDL60rGQf6rr=
c2AQbM99MEaVL4l-nk95sej3Lv98tvhstKVfs5fxWAz1Q$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Wed Sep 20 2023 - 08:29:58 MST