Email Archives for May, 2011 by thread
- AMMRL: Position Announcement : King Abdullah University of Science and Technology, Saudi Arabia Kazuo Yamauchi (Sun May 01 2011 - 01:57:52 MST)
- AMMRL: Z/E Alkene Coupling Constants Robin Kinnel (Mon May 02 2011 - 12:06:20 MST)
- AMMRL: 10 mm or 15 mm probe for B11 NMR Huang, Shaw (Tue May 03 2011 - 10:16:01 MST)
- AMMRL: question about VNMRJ in Linux Glenn A. Facey (Thu May 05 2011 - 06:05:40 MST)
- AMMRL: noesy and Topspin 3.0 Gabriel Gonzàlez (Thu May 05 2011 - 06:39:19 MST)
- AMMRL: 2011 NANUC NMR BootCamp announcement Deryck Webb (Thu May 05 2011 - 10:19:53 MST)
- AMMRL: 400 MHz NMR magnet/console for sale (or for free - depending on demand, England, UK). Mark Edgar (Fri May 06 2011 - 09:03:43 MST)
- AMMRL: 200 MHz 70mm bore magnet - Available Yong-Wah kim (Fri May 06 2011 - 15:02:58 MST)
- AMMRL: Pictures to explain relaxation Rainer Haessner (Sun May 08 2011 - 23:11:04 MST)
- AMMRL: possibility for PhD visitation Karel Klika (Tue May 10 2011 - 01:02:09 MST)
- AMMRL: vnmrj2.2D save data for 1H NMR not saving correctly under vnmrj2.2D Paul Ralifo (Tue May 10 2011 - 08:37:47 MST)
- AMMRL: power supplies for DRX AQX rack Robert Peterson (Tue May 10 2011 - 09:04:26 MST)
- AMMRL: need spare thermocouple for Bruker DPX300 Yang, Fei Dr. (Tue May 10 2011 - 11:25:24 MST)
- AMMRL: Question on diffusion experiments Francis Picart (Thu May 12 2011 - 12:17:43 MST)
- AMMRL:Safe vibration level for magets Tianzhi Wang (Mon May 16 2011 - 14:47:01 MST)
- AMMRL: NMR Spectroscopist - Oklahoma State U Blum, Frank (Tue May 17 2011 - 13:13:19 MST)
- AMMRL: Puzzled by DOSY on A+B Reaction Jerry Hu (Wed May 18 2011 - 10:41:55 MST)
- AMMRL: suggestions for modest continuous cooling needed Camass (Fri May 20 2011 - 07:13:32 MST)
- AMMRL: VT problem Wilbur, David J. (Fri May 20 2011 - 09:03:39 MST)
- AMMRL: 3mm probe design work Charles G. Fry (Fri May 20 2011 - 12:00:50 MST)
- AMMRL: XwinNMR 3.5 XP start-up problems Kirk Marat (Fri May 20 2011 - 16:11:36 MST)
- AMMRL: Gas Corinne Gibb (Mon May 23 2011 - 07:18:38 MST)
- AMMRL: X Windows Servers for Windows 7 Jacobsen, Neil E - (neil) (Tue May 24 2011 - 12:51:07 MST)
- AMMRL: center glitch problem on our INOVA-500 NMR Li, Wei (Tue May 24 2011 - 16:05:51 MST)
- AMMRL: power supplies for DRX AQX rack. Summary Robert Peterson (Fri May 27 2011 - 12:00:25 MST)
- AMMRL: NANUC NMR BootCamp Deryck Webb (Mon May 30 2011 - 14:29:10 MST)
- AMMRL: Bruker Solid State CPMAS rotors and caps Matthew Reid (Tue May 31 2011 - 10:17:13 MST)
- AMMRL: construction vibration and superconducting magnet Crawford, Susan (Tue May 31 2011 - 12:00:44 MST)
- AMMRL: Position Opening at UNL Walt Niemczura (Tue May 31 2011 - 13:26:18 MST)
- Last message date: Tue May 31 2011 - 10:26:42 MST
- Archived on: Sat Jun 17 2023 - 15:43:47 MST