Proton decoupled carbon-13 NMR of surfactant in CDCl3

From: Lawrence Byrnes <numare_at_ptd.net>
Date: Mon, 24 Apr 2006 15:30:59 -0400

Hello Spinlanders,

Have been trying to obtain proton decoupled 50 MHz carbon-13 NMR spectral
data for samples of DOW Chemical Tergitol NP-9, 5% and 20% V/V in CDCl3.
200 MHz proton NMR data is in good agreement with structure of
CH3-(CH2)8-C6H4-(OCH2CH2)9-OH. Proton decoupled carbon-13 NMR data for EO
portion of molecule is OK. Proton decoupled carbon-13 NMR data for phenyl
and aliphatic portions of molecule appear as fully coupled signals.

Is there some simple explanation for above observations? Is there a special
method required in order to obtain proton decoupled carbon-13 NMR spectral
data for this type of analytical sample?

If explanation and solution are offered, will post summary.

Thank you and kind regards,

Lawrence



Lawrence Byrnes

Laboratory Manager, Numare Spectralab Incorporated
Research Director, The Schoenenberg Institute of Molecular Spectroscopy
Hidden Meadow Farm, 3551 Winding Road
Kintnersville, PA, 18930-9543

610-346-8660 (voice)
610-346-7571 (fax)
numare_at_eclipse.net
www.eclipse.net/~numare/

Important notice! Please read!

This electronic mail (email), and any files transmitted with it, are
confidential and intended solely for the use of the individual or entity to
whom they are addressed. If you are not the intended recipient, you are not
permitted to distribute or use this message, or any of its attachments, in
any way. We also request that you advise the sender of the incorrect
addressing. This notice also confirms that this email message has been virus
scanned and that, although no computer viruses were detected, Numare
Spectralab Incorporated and The Schoenenberg Institute of Molecular
Spectroscopy accept no liability for any consequential damage resulting from
email containing any computer viruses. This email message may contain
legally privileged and/or confidential information. If you are not the
intended recipient(s), or the employee or agent responsible for the delivery
of this message to the intended recipient(s), you are hereby notified that
any disclosure, copying, distribution, or use of this email message is
prohibited. If you have received this message in error, please notify the
sender immediately by email and delete this email message from your
computer.

Thank you.
Received on Mon Apr 24 2006 - 19:27:30 MST

This archive was generated by hypermail 2.4.0 : Sun Jun 11 2023 - 14:32:03 MST