I don't know of any modern linux distribution that uses lilo by default
anymore. One can still use lilo if desired, but if Neal did not seek
out lilo when this system was initially set up, I doubt very seriously
if lilo is being used. Grub is usually the default boot manager.
(Having said that, I loved the simplicity of lilo when it was prevalent
many years ago!)
On 03/27/2012 11:26 AM, Ilangovan, Udayar wrote:
> Hi Neal,
>
> Can you give more info about your disk cloning process? Did you do the
> dd from ide disk to sata? I have cloned sata to sata without major
> problems. But, cloning ide to sata is always a problem (booting).
>
> When you tried to boot from new disk, did you disconnect your old system
> disk? If not, then you have to update your /etc/lilo.conf file and run
> lilo if you use lilo for boot loading.
>
> -Ilango.
>
> ------------------------------------------------------------------------
> *From:* Stolowich,Neal J. [stolowich_at_louisville.edu]
> *Sent:* Monday, March 26, 2012 5:10 PM
> *To:* AMMRL (ammrl_at_ammrl.org)
> *Subject:* AMMRL: RedHat problems update (long)
>
> Well, it seems like I'm a few steps closer to getting my Linux box
> running. From my initial plea for help below, I used SystemRescueCd
> (www.sysresccd.org <http://www.sysresccd.org>, thanks Bill!) and the
> ddrescue and GParted tools within. I cloned the failing drive sector by
> sector onto an identical size new hard drive. GParted confirmed that the
> exact partitions and filesystems were created on the new drive, and I
> could fsck the first 3, but not the last two. I tried booting from the
> RedHat rescue CD, and it did report the error that not all of the files
> were successfully mounted at /mnt/sysimage - although importantly it DID
> look like the directory structure of my failing drive, with /vnmr and
> /home apparently intact with directories (and data!) was there. I was
> still unable to fsck the last two partitions w/ the linux rescue cd as
> well. And of course, sometime during the initial fumbling around I had
> already tried to boot straight from the new drive as is, and it would
> begin to boot normally- up until the point of where it pauses for about
> 20 sec at:
>
> Red Hat nash version 5.x.x.x.x starting
>
> Then spits out the errors;
>
> INIT: cannot execute "/etc/X11/prefdm"
>
> INIT: Id "x" respawning too fast: disabling for 5 minutes
>
> and sits there. If I hit the enter key a few times I will get the
> following login which doesn't seem to take anything:
>
> (none) login:
>
> (obviously it doesn't know the "host" name yet)
>
> When going back to SystemRescue and checking GParted it did place a
> yellow exclamations next to these two partitions, noting that perhaps
> missing lvm2 software. Welcome to the world of logical volumes! Again,
> thanks to a link provided by Bill to a RedHat LVM cheat sheet, I think I
> did do something to get me closer (probably the command "vgchange") as
> now those exclamations in GParted went away and sda4 was now mounted on
> VolGroup00. I could now e2fsck the partition (as
> /dev/VolGroup00/LogVol00 , not as /dev/sda4), and now returning to the
> RH Linux rescue CD now successfully mounts the fs to /mnt/sysimage
> without any errors. So seemingly closer, but- I STILL can't boot up off
> the hard drive past the same point as before. (But at least the means
> are there for me to copy data if I choose to bail out of this "learning
> experience"!)
>
> One thing that I did notice on rebooting one of my good systems for
> comparison is that after the "Red Hat nash starting" pause, when it
> briefly mentions about checking the file systems, there's something
> about pressing "I" to interactive mode, so I figured I would try that,
> but these few sentences at this point go by so fast on the cloned
> system, and it didn't let me go into interactive startup (not that I was
> quick enough to do that on a good system as well!)
>
> So, I'm kind of stumped at this point. Could it be something as simple
> as maybe this file ("/etc/X11/prefdm) is bad? That file IS there, I
> checked once when mounted at /mnt/sysimage. (I'm thinking this must be
> the point it probably switches from the black low res screen to the
> higher res graphics with redhat border?) On the other hand, the failing
> system it would boot completely up, so I would think this file should be
> okay.
>
> Is there something else I'm failing to set for this boot up to work
> properly? Any other suggestions?
>
> Thanks for listening!
>
> Neal
>
> *From:*Stolowich,Neal J. [mailto:stolowich_at_louisville.edu]
> *Sent:* Thursday, March 15, 2012 11:56 AM
> *To:* AMMRL (ammrl_at_ammrl.org)
> *Subject:* AMMRL: RedHat problems
>
> Greetings all, I'm going through my own kind of "March Madness" here!
>
> In addition to my 700's cryobay unexplained shutdown and backup air
> compressor having a leak (taking down the 400 temporarily), I have a
> Dell running RH 5.3 on my 500 which appears to be having issues. It
> appears to boot up normally, with no errors when looking at the details.
> Log in screen, comes up and can enter user accounts (haven't tried them
> all) or root. Seems like if I log into root and open a terminal, the
> system seems stable and just sits there happily. But once I try to do
> stuff, whether through desktop applications, or via the terminal things
> go south in a hurry.
>
> Most applications will fail to launch, saying there a input/output errors.
>
> Some commands work within the terminal (when I can open it), but others
> - like shutdown give the error No such file or directory.
>
> I can log out of root, but can't restart or shutdown the computer from
> it. Usually, when logging out however I won't get back to the welcome
> screen, but just the black screen with a bunch of errors. (end_request:
> i/o error, dev sda , sector xxxxxxxx)
>
> Obviously, I must be having disk problems. I've never had issues with
> any of my RedHat systems before, while in the old day, the Sun's fsck
> seemed to fixed problems when they occurred. Any suggestions on trying
> to fix them?
>
> Thanks,
>
> Neal
>
> Neal J Stolowich, Ph.D.
>
> NMR Facilities Manager
>
> Department of Chemistry
>
> University of Louisville
>
> Louisville, Kentucky 40292
>
> Office: (502) 852-7894 Fax: (502) 852-8149
>
--
-Bill-
---------------------------------------------
Bill Gurley, Technical Director
Department of Chemistry
Univ. of Tennessee, Knoxville
865-974-3145 (office)
---------------------------------------------
Received on Wed Mar 28 2012 - 02:31:56 MST