From: Lawrence Byrnes <numare_at_ptd.net>
Date: Fri, 10 Mar 2006 12:57:11 -0500

Hello Spinlanders,

We recently attempted to evaluate a freeware computer based LIMS system with
hopes of replacing the tried and true paper trail with a more flexible
computerized version. The particular LIMS that we tried to implement is
called FNord from the DOE available from:
Information about the latest version along with an online demo can be found
at:
http://www.csm.ornl.gov/~geist/java/applets/enote/
The software for the latest version (1.12) is freely available for download.
You are free to customize it to your particular needs. The notebook
consists of a Perl-5 CGI script and library, and some supporting GIF
images. The computer you install the software on will need to have Perl-5
and a web server installed (since the
notebook is web-based). Each installation can manage multiple notebooks.
Users of the notebook do not need to install anything - all they need is a
web browser.
It is bundled up as either a tar file, or as a ZIP file,
You can get them directly from:
  http://www.csm.ornl.gov/~geist/enote/zips/enote1_12.tar
  http://www.csm.ornl.gov/~geist/enote/zips/enote1_12.zip
The distribution includes installation instructions and describes options
for customization to your particular needs. Installed, the entire notebook
package consumes less than 1 Mbyte (most of this is the gifs).

The online demos look very promising. Implementation on our own computer
system has been unsuccessful to date. Would like to hear from other folks
who have managed to get this LIMS system up and running on their lab's
computers. If you have successfully implemented a different freeware LIMS
in your lab, please send along a brief summary including current
availability.

Thank you and kind regards,

Lawrence




Lawrence Byrnes

Laboratory Manager, Numare Spectralab Incorporated
Research Director, The Schoenenberg Institute of Molecular Spectroscopy
Hidden Meadow Farm, 3551 Winding Road
Kintnersville, PA, 18930-9543

610-346-8660 (voice)
610-346-7571 (fax)
numare_at_eclipse.net
www.eclipse.net/~numare/

Important notice! Please read!

This electronic mail (email), and any files transmitted with it, are
confidential and intended solely for the use of the individual or entity to
whom they are addressed. If you are not the intended recipient, you are not
permitted to distribute or use this message, or any of its attachments, in
any way. We also request that you advise the sender of the incorrect
addressing. This notice also confirms that this email message has been virus
scanned and that, although no computer viruses were detected, Numare
Spectralab Incorporated and The Schoenenberg Institute of Molecular
Spectroscopy accept no liability for any consequential damage resulting from
email containing any computer viruses. This email message may contain
legally privileged and/or confidential information. If you are not the
intended recipient(s), or the employee or agent responsible for the delivery
of this message to the intended recipient(s), you are hereby notified that
any disclosure, copying, distribution, or use of this email message is
prohibited. If you have received this message in error, please notify the
sender immediately by email and delete this email message from your
computer.

Thank you.
Received on Fri Mar 10 2006 - 19:12:36 MST

This archive was generated by hypermail 2.4.0 : Sun Jun 11 2023 - 14:13:34 MST