Re: [AMMRL] Liquid nitrogen "on tap" inside an NMR room: your experience

From: Thomas Eubanks <thomas.eubanks_at_utrgv.edu>
Date: Wed, 7 Jun 2023 14:03:09 +0000

I guess if you can get the bulk plant or LN2 generator close enough.. be nice if you can pull it off.

________________________________
> From: main_at_ammrl.groups.io <main_at_ammrl.groups.io> on behalf of Cecile Le Duff via groups.io <c.s.leduff=bham.ac.uk_at_groups.io>
> Sent: Wednesday, June 7, 2023 8:31:13 AM
> To: main_at_ammrl.groups.io <main_at_ammrl.groups.io>
> Subject: [AMMRL] Liquid nitrogen "on tap" inside an NMR room: your experience


Dear colleagues,

As part of the design of a new Chemistry building, we are looking into getting
some liquid N2 "on tap", directly into the NMR room.

I am only aware of one NMR lab so far having implemented this (aside from biology
colleagues with small rooms, purpose-built for decanting) so I thought I'd pick
the brains in our community.



1/ Do you have such system installed and what do you use it for (decanting into
open top dewars, filling magnets, etc )?

                a/ What are your safety features?
                b/ Do you have specific training requirements for all coming into of the NMR facility?
                c/ if you are filling magnets with the system, are the flow rate/pressure reliable?
                d/ have you had any leaks?


2/ If you have considered such a system and have decided NOT to implement it, why did you decide against it?

                a/ price?
                b/reliability?
                c/resistance from Safety Services?
                d/other

Any experience/comments you shared on this will be greatly appreciated. Thank you!

I'll summarize the responses for the benefit of the group/archive.


Kind regards,

Cecile


------------------------------------

Dr Cecile S. LE DUFF
NMR Experimental Officer
School of Chemistry
University of Birmingham
Edgbaston B15 2TT
UK
Tel. + 44 (0) 121 414 4419
c.s.leduff_at_bham.ac.uk
------------------------------------


-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#166): https://urldefense.com/v3/__https://ammrl.groups.io/g/main/message/166__;!!PvDODwlR4mBZyAb0!RQ7n_8G_XkNlUip9nWSdSKgYhgv95WFBLcn8iD4IS03lT8HqpDyC1wP5veeWPzHsI1p8UzQRhtNF92l5QDarIM7-C38$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/99384696/7559972__;!!PvDODwlR4mBZyAb0!RQ7n_8G_XkNlUip9nWSdSKgYhgv95WFBLcn8iD4IS03lT8HqpDyC1wP5veeWPzHsI1p8UzQRhtNF92l5QDarxEHyAGM$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-




Received on Wed Jun 07 2023 - 07:03:21 MST

This archive was generated by hypermail 2.4.0 : Wed Oct 25 2023 - 14:42:24 MST