AMMRL: NIH Postdoctoral Position Available (1 of 2)

From: Fishbein, Kenneth (NIH/NIA/IRP) [E] <"Fishbein,>
Date: Mon, 22 Jun 2015 23:10:44 +0000

                Dear AMMRL Members,

                I would appreciate if you could post and forward the following postdoctoral fellowship advertisement below to any interested candidates. This is a position primarily dedicated to studies of human muscle aging on our 3T clinical MRI scanner and would have a start date in March 2016.

                                Best regards,

                                                Ken Fishbein

Kenneth W. Fishbein, Ph.D.
Facility Manager, MRI Section
National Institute on Aging
National Institutes of Health
251 Bayview Boulevard
BRC Room 04B120
Baltimore, MD 21224
(410) 558-8512
FAX: (410) 558-8376
Kf31x_at_nih.gov<mailto:Kf31x_at_nih.gov>

NIH POSTDOCTORAL POSITION AVAILABLE
MUSCULOSKELETAL NMR / MRI

            A postdoctoral position in musculoskeletal magnetic resonance is available, shared between the Longitudinal Study Section and the Magnetic Resonance Imaging and Spectroscopy Section at the National Institute on Aging (NIA) of the National Institutes of Health, located in Baltimore, Maryland. The work will center on spectroscopic and imaging studies of muscle in human subjects, mainly in the context of the Baltimore Longitudinal Study of Aging, one of the landmark studies of the National Institute on Aging. Investigation of diffusion, including anomalous diffusion, in the assessment of muscle quality and age-related muscle loss (sarcopenia) is a particular focus for this position. Results will be correlated with a wide range of other biological and functional outcomes to explore the basis and consequences of structural changes that occur with age and with age-associated disease. Other research opportunities may be available depending upon the interests and background of the successful candidate.
            The research associated with this position will be performed primarily using our 3T whole-body Philips Achieva MRI system, capable of both proton and heteronuclear spectroscopy. Other MRI instrumentation at the NIA consists of a triple-resonance vertical wide-bore 9.4T Bruker Avance III spectrometer with microimaging and solids capability and a double-resonance Bruker 7T/30 cm Biospec Avance system for preclinical studies.
            A background in MR imaging or NMR spectroscopy of muscle or connective tissue is preferred, although applications are also invited from individuals with experience in other areas of biological MRI and NMR. In addition, experience with methods development and pulse programming on clinical MR instruments is highly desirable. All applicants must have Ph.D. level training and experience in magnetic resonance. The appointment will be as an IRTA Postdoctoral Fellow for US citizens or as a Visiting Fellow for non-citizens. Accordingly, applicants must have fewer than five years of postdoctoral experience.
            This position will be available in March, 2016. Interested individuals should e-mail their CV and the names, telephone numbers, and e-mail addresses of at least three references to: Dr. Richard Spencer, Magnetic Resonance Imaging and Spectroscopy Section, NIH/NIA, BRC Room 04B116, 251 Bayview Boulevard, Baltimore, MD 21224; Tel. 410-558-8226; e-mail: spencer_at_helix.nih.gov<mailto:spencer_at_helix.nih.gov>

websites:

http://www.irp.nia.nih.gov/branches/lci/nmr/nmr.htm

http://www.irp.nia.nih.gov/branches/tgb/tgb.htm


The NIH is an equal opportunity employer. Minorities and women are especially encouraged to apply.
Received on Mon Jun 22 2015 - 13:10:52 MST

This archive was generated by hypermail 2.4.0 : Mon Jun 19 2023 - 16:07:33 MST