Dear NMR users,
as far as I know, a mail has already informed you about the 'vconv' command in TopSpin. To the best of my knowledge, (almost) all VNMR datasets are handled correctly by 'vconv'. One thing that's a bit hard for us to find out is the correct "MC2" flag for the Bruker processing. You can create a parameter set with the name of the VNMR pulse program and set "MC2" in it. If such a parameter set exists, it will be used as the base parameter set for the converted dataset and MC2 is correct from the start.
If you encounter problems with the conversion, you can always send this VNMR dataset to nmr-software-support_at_bruker.de and we'll have a look.
Best wishes, Mike !
Bitte die neue Telefonnummer beachten - Please note the new phone number
Bruker BioSpin GmbH
Dr. Michael Engelhardt
Service Manager
Bruker BioSpin GmbH
Silberstreifen
76287 Rheinstetten
Germany
Phone: +49 721 5161-6440
Fax: +49 721 5161-91440
michael.engelhardt_at_bruker-biospin.de
www.bruker-biospin.com
Bruker BioSpin GmbH: Sitz der Gesellschaft/Registered Office: Rheinstetten, HRB 102368 Amtsgericht Mannheim
Geschäftsführer/Managing Directors: Dr. Bernd Gewiese, Dr. Dieter Schmalbein, Dr. Gerhard Roth
Diese E-Mail und alle Anlagen können Betriebs- oder Geschäftsgeheimnisse, oder sonstige vertrauliche Informationen enthalten. Sollten Sie diese E-Mail irrtümlich erhalten haben, ist Ihnen eine Kenntnisnahme des Inhalts, eine Vervielfältigung oder Weitergabe der E-Mail und aller Anlagen ausdrücklich untersagt. Bitte benachrichtigen Sie den Absender und löschen/vernichten Sie die empfangene E-Mail und alle Anlagen.
Vielen Dank.
This message and any attachments may contain trade secrets or privileged, undisclosed or otherwise confidential information. If you have received this e-mail in error, you are hereby notified that any review, copying or distribution of it and its attachments is strictly prohibited. Please inform the sender immediately and delete/destroy the original message and any copies.
Thank you.
> -----Ursprüngliche Nachricht-----
> Von: Charles G. Fry [mailto:cgfry_at_wisc.edu]
> Gesendet: Fr 10.07.2009 19:15
> An: ammrl
> Cc:
> Betreff: AMMRL: TopSpin data imports
>
>
>
> Hi all,
>
> I have had some students recently asking me questions about TopSpin
> (e.g., postdocs that have used it elsewhere). In particular, they want
> to know whether the software can import Varian data sets.
>
> I have not used TopSpin, but have imported Varian data into XwinNMR
> in
> the past with varying success. It would be helpful to hear from any
> TopSpin users out there in AMMRL land that import Varian spectra how
> well that works for you.
>
> Cheers,
> Charlie
>
>
>
>
> ~~~~~~~~~~~~~~~~~~~~~~~
> Charles G. Fry, Ph.D. Tel: (608)262-3182
> Director, MR Facility Fax: (608)262-0381
> Chem. Dept., 1101 University Ave, Univ. Wisconsin-Madison
> Madison, WI 53706 USA email: fry_at_chem.wisc.edu
>
>
>
>
Received on Tue Jul 14 2009 - 04:58:02 MST