RE: converting old GE data

From: Woodrow Conover <woody_at_acornnmr.com>
Date: Wed, 9 Jan 2002 13:51:11 -0800

Howdy All,

We recently added to our NUTS shareware version (free for 30 days) the
ability to export JCAMP-DX5 NTUPLES 1D data. 2D exports are supported in
the NUTS 2D Pro version but 1D files only are supported in the shareware
version. The shareware version of NUTS does import the files in
question. User could imported the data in question and exported a
JCAMP-DX5 NTUPLES file.

http://www.acornnmr.com/shareware.htm

vnmr and xwinnmr are reported to be able to import JCAMPDX-5 files but
some of our customers report problems on those platforms importing
NUTS's exported JCAMPDX-5 NTUPLES files. We have addressed many of the
reported problems, but I expect there are more "gotchas". The problem
here is that the JCAMP-DX5 NTUPLES "standard" has a very loose
definition with lots of room for "vendor specific parameters" which can
create problems. NUTS does read and write files compatible with the
test files posted on the web by the JCAMP organization, but I am unsure
that vnmr or xwinnmr can read NUTS's JCAMP-DX5 NTUPLES exports. If these
programs do read the exported files, then this would be a way to
transfer spectra from the MANY file formats supported by NUTS to any
program that can read JCAMP-DX5 NTUPLES files.

If anyone tries this, I would appreciate reports. If there are problems
we can identify then we can correct them.

woody_at_acornnmr.com




> -----Original Message-----
> From: Shaoxiong Wu [mailto:swu_at_learnlink.emory.edu]
> Sent: Tuesday, January 08, 2002 1:21 PM
> To: fqiu_at_bmb-fs1.biochem.okstate.edu
> Cc: ammrl_at_chemnmr.colorado.edu
> Subject: Re: converting old GE data
>
>
> I know how to convert it to felix. and also we use
> nut to process these data.
>
> Do you still have QE300? I could connect
> it with a PC and then transfer the data diretly to PC and
> process and print the spectra by PC by using NUTS.
>
> Shaoxiong Wu
> Emory
>
> fqiu_at_bmb-fs1.biochem.okstate.edu writes:
> >Hello, all,
> >Is there any convrting utility to convert QE300 or GN500
> data to either
> >vnmr or xwinnmr format? Thanks.
> >Feng Qiu
> >
> >-- =============================================================
> >| Feng Qiu, Ph.D. Department of Chemistry |
> >| Director of NMR Facility Temple University |
> >| Office: (215)204-1052 Philadelphia, PA 19122 |
> >| FAX: (215)204-1532 mailto:fqiu_at_biochem.okstate.edu |
> >=============================================================
>
Received on Wed Jan 09 2002 - 18:35:59 MST