Re: hackers on bruker SGIs

Gary Strahan (strahan@mmiris.ab.umd.edu)
Mon, 8 Feb 1999 10:35:05 -0500

Thanks for notifying me (us) about the potential conflict
between shadow passwds and xwinnmr. I have not had this
experience (yet?).

Gary

On Feb 6, 2:09pm, camass wrote:
> Subject: Re: hackers on bruker SGIs
> Dear Ammrl's
> We have an o2 running 6.3 and brukers next to
> last xwinnmr. using shadow passwords can be a
> problem if you try to change parts of xwinnmr
> requiring the superuser password. the program
> can have problems in not recognizing the
> password and if you try to turn off shadowing it
> can produce a machine lockup requiring single
> user mode to get back in.
> Yours
> Charles Amass
>
> Gary Strahan wrote:
> >
> > Hi John,
> >
> > This is a flaw in many SGI machines. There are, in fact, several
> > user accounts which allow one to enter these machines with out passwords.
> > Make sure that your Sys Admin has not only given all accounts passwords,
> > but that he has assigned the shell and directories to /dev/null.
> > You might also wish to start using shadow passwords.
> >
> > nobody:x:60001:60001:SVR4 nobody uid:/dev/null:/dev/null
> >
> > Hopefully, your hacker has not installed any back doors into your
> > machines.
> >
> > Gary
> >
> > On Feb 4, 5:33pm, John Chung wrote:
> > > Subject: hackers on bruker SGIs
> > >
> > > Howdy
> > >
> > > Just wanted to let the Bruker users community know that the O2's
> > > and some Indy's that come as defaults on the newer Avance machines
> > > have security holes in the password file which have allowed some
> > > hacker to get into 3 of our Avance machines recently (two O2's on
> > > DRX and one Indy on DMX) as the login
> > >
> > > lp
> > >
> > > No damage seems to have been done, and we even have the IP address
> > > of where the person came from (probably a temporary/anon account on the
> > > uu.net ISP and not worth trying to pursue who exactly it was), but
> > > the person had given the lp login passwords (i.e., created him/herself
> > > a backdoor).
> > > In case you're wondering how we know this, you can do
> > > cd /var/adm
> > > last
> > > and look for login as username 'lp'
> > > you can also do
> > > last -f OLDwtmp
> > > last -f OLDwtmpx
> > > to look at older logins (see manpages on last)
> > >
> > > I advise people with Bruker supplied SGI boxes to at least check
> > > the /etc/passwd files (do a simple 'grep ::') to see if there are
> > > any lines without passwords (nuucp is another that had no password).
> > > Put in a simple * in the blank password fields.
> > >
> > > Our system admin gurus installed a number of patches on all these
> > > newer machines. In case you're interested, they're summarized below.
> > >
> > > John Chung
> > > The Scripps Research Institute
> > >
> > > ---------
> > >
> > > The patches on O2 (IRIX 6.3) from the 'versions -b' command are:
> > >
> > > I patchSG0001695 01/29/99 Patch SG0001695: Fix License Manager
> > security hole by removing setuid program
> > > I patchSG0002044 01/29/99 Patch SG0002044: rld rollup #7 for 6.2,
> > 6.3, and 6.4: pthreads+security
> > > I patchSG0002133 01/29/99 Patch SG0002133: talkd security
> > > I patchSG0002168 01/29/99 Patch SG0002168: Fix for lpd lock file
> > access for IRIX 6.3
> > > I patchSG0002213 01/29/99 Patch SG0002213: IRIX 6.2/6.3/6.4
ordist
> > Security
> > > I patchSG0002792 01/29/99 Patch SG0002792 : pset security
> > vulnerability
> > > I patchSG0002869 01/29/99 Patch SG0002869: Netware Client fixes
for
> > IRIX 6.3
> > > I patchSG0003068 01/29/99 Patch SG0003068: Cgi script security
> > vulnerability
> > > I patchSG0003144 01/29/99 Patch SG0003144: xterm security fix
> > > I patchSG0003394 01/29/99 Patch SG0003394: mail security fix (for
6.3
> > and 6.4)
> > >
> > >
> > > And for Indy (IRIX 5.3)
> > >
> > > I patchSG0001685 01/29/99 Patch SG0001685 : netprint security
patch
> > for IRIX 5.3 and 6.1
> > > I patchSG0002132 01/29/99 Patch SG0002132: talkd security
> > > I patchSG0002176 01/29/99 Patch SG0002176: pset security
vulnerabilty
> > > I patchSG0002212 01/29/99 Patch SG0002212: IRIX 5.3 ordist
security
> > > I patchSG0002216 01/29/99 Patch SG0002216: login/scheme fix for
> > buffer overrun security issue and LOCKOUT option
> > > I patchSG0002228 01/29/99 Patch SG0002228: Security patch for
eject
> > > I patchSG0003142 01/29/99 Patch SG0003142: xterm wtmp and
security
> > fixes
> > > I patchSG0003189 01/29/99 Patch SG0003189 ISO9660 reading and
> > security fixes
> > >
> > >
> > >
> > > ---------------------------
> > > chung@scripps.edu
> > > ---------------------------
> > >-- End of excerpt from John Chung
> >
> > --
> > _____________________________________________________________________
> >
> > Gary Strahan, Ph.D. strahan@mmiris.ab.umd.edu
> > Department of Pharmaceutical Sciences Phone: USA-410-706-3118
> > University of Maryland at Baltimore FAX: USA-410-706-0346
> > _____________________________________________________________________
> >
> > Under US Code Title 47, Sec.227(b)(1)(C), Sec.227(a)(2)(B)
> > This email address may not be added to any commercial mail
> > list with out my permission. Violation of my privacy with
> > advertising or SPAM will result in a suit for a MINIMUM of
> > $500 damages/incident, $1500 for repeats.
>-- End of excerpt from camass

-- 
_____________________________________________________________________

Gary Strahan, Ph.D. strahan@mmiris.ab.umd.edu Department of Pharmaceutical Sciences Phone: USA-410-706-3118 University of Maryland at Baltimore FAX: USA-410-706-0346 _____________________________________________________________________

Under US Code Title 47, Sec.227(b)(1)(C), Sec.227(a)(2)(B) This email address may not be added to any commercial mail list with out my permission. Violation of my privacy with advertising or SPAM will result in a suit for a MINIMUM of $500 damages/incident, $1500 for repeats.