Zhe (Frank) Zhou, Ph.D.
Co-Director of NMR Research Center
College of Basic Sciences, Louisiana State University
Baton Rouge, LA 70803, USA
Email: zzhou1_at_lsu.edu
Office: (225)-578-3460
Fax: (225)-578-3458
=======================
ICRASH CORE FILE REPORT
=======================
SYSTEM:
system name: IRIX
release: 6.5
node name: chb18a
version: 04151556
machine name: IP32
GENERATED ON:
Mon Feb 18 09:41:15 2002
TIME OF CRASH:
1013839922 Sat Feb 16 00:12:02 2002
PANIC STRING:
PANIC: TLBMISS: KERNEL FAULT
NAMELIST:
/unix [CREATE TIME: Wed Jun 30 08:55:36 1999]
COREFILE:
/dev/swap [CREATE TIME: Mon Feb 18 09:40:31 2002]
================
COREFILE SUMMARY
================
The system was brought down due to an internal panic.
===========
PUTBUF DUMP
===========
tatistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<0>PANIC: TLBMISS: KERNEL FAULT
PC: 0x80122a50 ep: 0x80361ef0
EXC code:8, `Read TLB Miss '
Bad addr: 0xff800000, cause: 0x108<CE=6145
<6>
Dumping to
/hw/node/io/pci/1/scsi_ctlr/0/target/1/lun/0/disk/partition/1/block at block 0,
space: 0x8000 pages
<6>Dumping low memory...<6>
<6>Dumping static kernel pages...<6>.<6>.<6>.1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: statistics overflow
<4>WARNING: ec1: s H
===========
CPU SUMMARY
===========
CPU 0 was servicing an interrupt
STACK TRACE:
================================================================
STACK TRACE FOR XTHREAD 0x8087fc00 (crime_intr(10)):
1 dumpsys[../os/vmdump.c: 282, 0x801c8518]
2 syncreboot[../os/printf.c: 1532, 0x80198584]
3 icmn_err[../os/printf.c: 558, 0x80197044]
4 cmn_err[../os/printf.c: 150, 0x801965bc]
5 panicregs[../os/trap.c: 254, 0x8015f3f4]
6 tlbmiss[../os/trap.c: 3233, 0x80162a00]
7 VEC_tlbmiss[../ml/LOCORE/vec_tlbmiss.s: 41, 0x80018cfc]
r0/zero:0000000000000000 r1/at:ffffffffffff8000 r2/v0:0000000000000000
r3/v1:0000000000010000 r4/a0:ffffffff8036f240 r5/a1:0000000000000801
r6/a2:0000000000000001 r7/a3:ffffffff80388ae8 r8/a4:ffffffff8090b800
r9/a5:ffffffff81593000 r10/a6:ffffffff80388af8 r11/a7:0000000000000000
r12/t0:0000000000000008 r13/t1:0000000000000008 r14/t2:ffffffffb4000018
r15/t3:0000000000000000 r16/s0:ffffffff8036f240 r17/s1:ffffffff8087fc00
r18/s2:ffffffff80896cf8 r19/s3:ffffffff8033e670 r20/s4:0000000000001801
r21/s5:ffffffff8038fad0 r22/s6:ffffffff80362128 r23/s7:ffffffffffffffff
r24/t8:0000000000000000 r25/t9:ffffffff8000e20c r26/k0:ffffffff80362164
r27/k1:ffffffff80896cf8 r28/gp:ffffffff80371e30 r29/sp:ffffffff80362058
r30/s8:0000000000000801 r31/ra:ffffffff80122584 EPC:ffffffff80122a50
CAUSE=108, SR=8403, BADVADDR=ffffffffff800000
8 semadq[../os/ksync/sema.c: 1237, 0x80122a50]
9 semawake[../os/ksync/sema.c: 648, 0x8012257c]
10 vsema[../os/ksync/sema.c: 1019, 0x80122924]
11 clock[../os/clock.c: 755, 0x8013da8c]
12 synthclock[../ml/MOOSEHEAD/IP32intr.c: 237, 0x8000c954]
13 crime_intr[../ml/MOOSEHEAD/IP32intr.c: 456, 0x8000cd78]
14 intr[../ml/MOOSEHEAD/IP32intr.c: 543, 0x8000cec4]
15 VEC_int[../ml/LOCORE/vec_int.s: 84, 0x800021c8]
r0/zero:0000000000000000 r1/at:fffffffffffffffe r2/v0:0000000000000001
r3/v1:0000000000000000 r4/a0:0000000000008701 r5/a1:000000000000002c
r6/a2:0000000020000000 r7/a3:0000000000000000 r8/a4:0000000000000010
r9/a5:0000000000000000 r10/a6:ffffffff8087fc00 r11/a7:0000000000000000
r12/t0:0000000000000000 r13/t1:00000000343f03f8 r14/t2:ffffffffb4000018
r15/t3:0000000000000000 r16/s0:ffffffff80891000 r17/s1:0000000000000000
r18/s2:0000000000008700 r19/s3:0000000000000001 r20/s4:0000000000000000
r21/s5:0000000000000000 r22/s6:0000000000000000 r23/s7:ffffffff8090b800
r24/t8:ffffffff8000cbbc r25/t9:fffffffffffffbff r26/k0:0000000000000000
r27/k1:ffffffff8090b800 r28/gp:0000000000000000 r29/sp:ffffffff80896e60
r30/s8:00000000000c0000 r31/ra:ffffffff80043834 EPC:ffffffff80043834
CAUSE=400, SR=8703, BADVADDR=ffffffffc000b020
16 pciio_pio_read32[../io/pcimh.c: 1848, 0x80043834]
17 if_ecfintr[../bsd/mips/if_ecf.c: 548, 0x80090bf4]
18 crimevec_intrd[../ml/MOOSEHEAD/IP32intr.c: 954, 0x8000d778]
19 xthread_prologue[../os/swtch.c: 1611, 0x801b9228]
20 xtresume[../os/swtch.c: 1660, 0x801b92e0]
================================================================
=======================
CRASH SUMMARY FOR CPU 0
=======================
1 dumpsys[../os/vmdump.c: 282, 0x801c8518]
2 syncreboot[../os/printf.c: 1532, 0x80198584]
3 icmn_err[../os/printf.c: 558, 0x80197044]
4 cmn_err[../os/printf.c: 150, 0x801965bc]
5 panicregs[../os/trap.c: 254, 0x8015f3f4]
6 tlbmiss[../os/trap.c: 3233, 0x80162a00]
7 VEC_tlbmiss[../ml/LOCORE/vec_tlbmiss.s: 41, 0x80018cfc]
r0/zero:0000000000000000 r1/at:ffffffffffff8000 r2/v0:0000000000000000
r3/v1:0000000000010000 r4/a0:ffffffff8036f240 r5/a1:0000000000000801
r6/a2:0000000000000001 r7/a3:ffffffff80388ae8 r8/a4:ffffffff8090b800
r9/a5:ffffffff81593000 r10/a6:ffffffff80388af8 r11/a7:0000000000000000
r12/t0:0000000000000008 r13/t1:0000000000000008 r14/t2:ffffffffb4000018
r15/t3:0000000000000000 r16/s0:ffffffff8036f240 r17/s1:ffffffff8087fc00
r18/s2:ffffffff80896cf8 r19/s3:ffffffff8033e670 r20/s4:0000000000001801
r21/s5:ffffffff8038fad0 r22/s6:ffffffff80362128 r23/s7:ffffffffffffffff
r24/t8:0000000000000000 r25/t9:ffffffff8000e20c r26/k0:ffffffff80362164
r27/k1:ffffffff80896cf8 r28/gp:ffffffff80371e30 r29/sp:ffffffff80362058
r30/s8:0000000000000801 r31/ra:ffffffff80122584 EPC:ffffffff80122a50
CAUSE=108, SR=8403, BADVADDR=ffffffffff800000
8 semadq[../os/ksync/sema.c: 1237, 0x80122a50]
9 semawake[../os/ksync/sema.c: 648, 0x8012257c]
10 vsema[../os/ksync/sema.c: 1019, 0x80122924]
11 clock[../os/clock.c: 755, 0x8013da8c]
12 synthclock[../ml/MOOSEHEAD/IP32intr.c: 237, 0x8000c954]
13 crime_intr[../ml/MOOSEHEAD/IP32intr.c: 456, 0x8000cd78]
14 intr[../ml/MOOSEHEAD/IP32intr.c: 543, 0x8000cec4]
15 VEC_int[../ml/LOCORE/vec_int.s: 84, 0x800021c8]
r0/zero:0000000000000000 r1/at:fffffffffffffffe r2/v0:0000000000000001
r3/v1:0000000000000000 r4/a0:0000000000008701 r5/a1:000000000000002c
r6/a2:0000000020000000 r7/a3:0000000000000000 r8/a4:0000000000000010
r9/a5:0000000000000000 r10/a6:ffffffff8087fc00 r11/a7:0000000000000000
r12/t0:0000000000000000 r13/t1:00000000343f03f8 r14/t2:ffffffffb4000018
r15/t3:0000000000000000 r16/s0:ffffffff80891000 r17/s1:0000000000000000
r18/s2:0000000000008700 r19/s3:0000000000000001 r20/s4:0000000000000000
r21/s5:0000000000000000 r22/s6:0000000000000000 r23/s7:ffffffff8090b800
r24/t8:ffffffff8000cbbc r25/t9:fffffffffffffbff r26/k0:0000000000000000
r27/k1:ffffffff8090b800 r28/gp:0000000000000000 r29/sp:ffffffff80896e60
r30/s8:00000000000c0000 r31/ra:ffffffff80043834 EPC:ffffffff80043834
CAUSE=400, SR=8703, BADVADDR=ffffffffc000b020
16 pciio_pio_read32[../io/pcimh.c: 1848, 0x80043834]
17 if_ecfintr[../bsd/mips/if_ecf.c: 548, 0x80090bf4]
18 crimevec_intrd[../ml/MOOSEHEAD/IP32intr.c: 954, 0x8000d778]
19 xthread_prologue[../os/swtch.c: 1611, 0x801b9228]
20 xtresume[../os/swtch.c: 1660, 0x801b92e0]
Received on Fri Feb 22 2002 - 17:50:30 MST
This archive was generated by hypermail 2.4.0 : Mon Jun 05 2023 - 14:34:31 MST