This is a multi-part message in MIME format.
------=_NextPart_000_001D_01C84C9C.D2B510F0
Content-Type: text/plain;
charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable
To all: Sadly, Ben Hamilton of Magnetic Resonance Services Inc, has =
passed away. Ben died on 23Dec at his home. His funeral was held on =
28Dec in Round Rock, TX. Ben will be greatly missed by his family, =
friends and colleagues. Please pass this message along to those of =
interest. Thank you.
The family of Ben Hamilton.
----- Original Message -----=20
From: Fishbein, Kenneth (NIH/NIA/IRP) [E]=20
To: ammrl@chemnmr.colorado.edu=20
Sent: Friday, December 14, 2007 6:37 PM
Subject: AMMRL: MRI Console Needed, MRI Magnet Trade-in
Dear AMMRL Members,
=20
We would like to purchase a new or used 300 MHz console for animal =
MRI/NMR research. We have a 7.0T/210mm Magnex magnet, Magnex 120 mm =
shielded gradients, a CPC 1 kW 1H RF amplifier, a Copley 256 gradient =
amplifier rack and a RRI shim power supply. We need the digital and =
low-level RF components to complete this system. Possible consoles =
include new or used Bruker Avance DBX and Varian Inova and MRI consoles, =
as well as similar products from other vendors.
We have the following equipment to trade in toward the =
purchase of the 300 MHz console:
=20
1.. A complete 1.9T / 310 mm Bruker ABX Biospec MRI, including =
Oxford magnet, Bruker BGA20 gradients, Bruker console and several Bruker =
coils=20
2.. A GE Signa console customized for preclinical (animal) MRI.=20
3.. Other MRI/NMR hardware and spare parts, including two Wavetek =
sweep generators, nine Techron 8607 gradient amplifiers and numerous =
spare parts for the GE Signa console.=20
=20
We are also interested in the possibility of trading our (unshielded) =
Magnex 7T / 210mm magnet for a new or used shielded 9.4T / 210mm or =
11.7T / 210mm magnet. The trade in could also include any of the =
hardware described above. We would then also need to buy a suitable 400 =
MHz or 500 MHz MRI/NMR console in lieu of the 300 MHz console. I would =
appreciate your suggestions on how to conduct this trade so that NIH =
gets the best animal MRI system for the least cost.
=20
Best regards,
=20
Ken Fishbein
Facility Manager, MRI Section
NIH/NIA/IRP
=20
=20
=20
Kenneth W. Fishbein, Ph.D.
National Institutes of Health
National Institute on Aging
Gerontology Research Center Room 4D-08
5600 Nathan Shock Drive
Baltimore, MD 21224 USA
Phone: (410) 558-8512
FAX: (410) 558-8376
E-mail: kf31x@nih.gov
=20
------=_NextPart_000_001D_01C84C9C.D2B510F0
Content-Type: text/html;
charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable
To all: Sadly, Ben Hamilton of Magnetic =
Resonance=20
Services Inc, has passed away. Ben died on 23Dec at his home. His =
funeral was=20
held on 28Dec in Round Rock, TX. Ben will be greatly missed by his =
family,=20
friends and colleagues. Please pass this message along to those of =
interest.=20
Thank you.
The family of Ben =
Hamilton.
----- Original Message -----
Sent: Friday, December 14, 2007 =
6:37=20
PM
Subject: AMMRL: MRI Console =
Needed, MRI=20
Magnet Trade-in
Dear AMMRL=20
Members,
We would=20
like to purchase a new or used 300 MHz console for animal MRI/NMR =
research. We=20
have a 7.0T/210mm Magnex magnet, Magnex 120 mm shielded gradients, a =
CPC 1 kW=20
1H RF amplifier, a Copley 256 gradient amplifier rack and a RRI shim =
power=20
supply. We need the digital and low-level RF components to complete =
this=20
system. Possible consoles include new or used Bruker Avance DBX and =
Varian=20
Inova and MRI consoles, as well as similar products from other=20
vendors.
=
=20
We have the following equipment to trade in toward the purchase of the =
300 MHz=20
console:
- A =
complete 1.9T /=20
310 mm Bruker ABX Biospec MRI, including Oxford magnet, Bruker BGA20 =
gradients, Bruker console and several Bruker coils =
- A GE =
Signa console=20
customized for preclinical (animal) MRI.
- Other =
MRI/NMR=20
hardware and spare parts, including two Wavetek sweep generators, =
nine=20
Techron 8607 gradient amplifiers and numerous spare parts for the GE =
Signa=20
console.
We are=20
also interested in the possibility of trading our (unshielded) Magnex =
7T /=20
210mm magnet for a new or used shielded 9.4T / 210mm or 11.7T / 210mm =
magnet.=20
The trade in could also include any of the hardware described above. =
We would=20
then also need to buy a suitable 400 MHz or 500 MHz MRI/NMR console in =
lieu of=20
the 300 MHz console. I would appreciate your suggestions on how to =
conduct=20
this trade so that NIH gets the best animal MRI system for the least=20
cost.
=
=
Best regards,
=
&=
nbsp; =20
Ken Fishbein
=
&=
nbsp; =20
Facility Manager, MRI Section
=
&=
nbsp; =20
NIH/NIA/IRP
Kenneth W.=20
Fishbein, Ph.D.
National=20
Institutes of Health
National=20
Institute on Aging
Gerontology Research =
Center Room=20
4D-08
5600=20
Nathan Shock Drive
Baltimore,=20
MD 21224 USA
Phone: (410)=20
558-8512
FAX: (410)=20
558-8376
E-mail:=20
kf31x@nih.gov
------=_NextPart_000_001D_01C84C9C.D2B510F0--