I think it is only fitting that an old Bruker dewar return as a kegerator.
Mike Delk
Mike Delk
University of Pittsburgh
School of Medicine
Department of Structural Biology
412.370.0066
________________________________
From: main_at_ammrl.groups.io <main_at_ammrl.groups.io> on behalf of Mark Conradi=
via groups.io <msc=wuphys.wustl.edu_at_groups.io>
Sent: Thursday, August 31, 2023 7:17:43 PM
To: main_at_ammrl.groups.io <main_at_ammrl.groups.io>
Subject: Re: [AMMRL] AMMRL: What to do with old magnets?
Jeff,
Like to smoke meats?
I hope you are enjoying,
Mark
On Thu, 31 Aug 2023, Jeff Walton via groups.io wrote:
> Nobody has mentioned turning it into a smoker. I know somebody has done it and saw a pic, but
> can’t remember who. And my quick search turned up nothing. Anyone know the particulars?
> Best,
>
> Jeff
>
> On Aug 29, 2023, at 12:49 PM, Kaden, Dr. Peter via groups.io
> <p.kaden=hzdr.de_at_groups.io> wrote:
>
> Maybe an interesting article for you all:
> <Vorschau.png>
> No-Flux-Left-To-Give
> PDF-Dokument · 23,2 MB
>
> Cheers,
> Peter
>
> _HZDR | Institute of Resource Ecology | Chemistry of the f-elements
> Telefon: +49 (0351) 260 2261
> Email: p.kaden_at_hzdr.de
>
> Am 29.08.2023 um 20:55 schrieb Spin-Doc <bert.heise_at_spin-doc.net>:
>
> Hi Rick,
> also because Jonathan Lee (via PM) pointed it out to me, let me be a bit more
> specific:
> - (un)welding but possibly also angle grinding stainless steel can and will produce
> toxic (chromium) fumes, thus it is advised to do this
> a) outside
> b) under forced fume extraction / dispersing fumes away from you and anyone else
> c) wearing suitable personal protection equipment (screen, gloves, gas mask)
>
> Also, as Rick correctly observed (and this indeed happened to me the first time I did
> this…), the mylar foil between the outer stainless shell and the nitrogen dewar will
> happily ignite when using a plasma cutter… I usually remove the bottom plate and
> central bores, then rip out the super insulation as much as possible before going at
> it with the cutter.
>
> Cheers
> Bert
>
> -> Sent via mobile <-
>
> Spin-Doc Magnetic resonance equipment, service, training & more
> Dr. rer. nat. Bert Heise Owner, applications scientist
> Kiefernweg 13
> 58239 Schwerte
> Germany
-=-=-=-=-=-=-=-=-=-=-=-
Groups.io Links: You receive all messages sent to this group.
View/Reply Online (#515): https://urldefense.com/v3/__https://ammrl.groups.=
io/g/main/message/515__;!!PvDODwlR4mBZyAb0!X6Wg7sloEsk76NbacXPabOJ3d_KaLjve=
VBHSdTB2ob8gH4keZVsxsozpGmmLRlFXhI_fa3RwXyqhbQ$
Mute This Topic: https://urldefense.com/v3/__https://groups.io/mt/100963604=
/7559972__;!!PvDODwlR4mBZyAb0!X6Wg7sloEsk76NbacXPabOJ3d_KaLjveVBHSdTB2ob8gH=
4keZVsxsozpGmmLRlFXhI_fa3QYKnWtYg$
Group Owner: main+owner_at_ammrl.groups.io
-=-=-=-=-=-=-=-=-=-=-=-
Received on Thu Aug 31 2023 - 16:24:47 MST