RE: VT-connector on Varian probes

From: <dick.taylor_at_dowcorning.com>
Date: Fri, 27 Aug 2004 20:56:00 -0400

Jan,
We feel the same way. The VT connection is a long standing problem on Varian
probes for which we have no good solution. I would very much like to see a
moe reliable connection on an otherwise fine probe. Now that Varian has
acquired Nalorac, maybe they will move to a bottom plug design rather than
the side. Other than the difficulty in aligning the sockets, the connections
are reliable.

Regards,

Dick Taylor
Associate Research Scientist, NMR
Dow Corning Corp
phone: (989)496-5594
e-mail: dick.taylor_at_dowcorning.com

-----Original Message-----
> From: schraml_at_icpf.cas.cz [mailto:schraml_at_icpf.cas.cz]
> Sent: Friday, August 27, 2004 1:38 AM
> To: janm_at_science.uva.nl; ammrl_at_ammrl.org
> Subject: RE: VT-connector on Varian probes


 Dear fellows Varian VT probe users,

I am not sure to what extent it is in line with "ammrl" policy but I
would like to start a discussion on the VT connectors on Varian probes.

In our laboratory the connector is a permanent source of troubles on
otherwise excellent probes (and spectrometers).

If you look at the recently introduced AutoX probe, you see the same
obsolete connector used again.

I cannot believe that ours is the only laboratory complaining about
these connectors?
Has anybody found a good solution eliminating the losses of VT control
(besides using rubber bands)?

With the best regards,
Jan Schraml


*******************************************************
Prof. Jan Schraml, DrSc
NMR laboratory, Head
Institute of Chemical Process Fundamentals
Academy of Sciences, Czech Republic
Rozvojova 135
Prague 6, 165 02
Czech Republic
Tel: (+420) 220 390 315 or (+420) 296 780 315
Fax: (+420) 220 390 357 or (+420) 296 780 357
         or (+420) 220 92 06 61 - central office
e-mail: schraml_at_icpf.cas.cz


-----Original Message-----
> From: J.M. Ernsting [mailto:janm_at_science.uva.nl]
> Sent: Thursday, August 26, 2004 10:02 AM
> To: ammrl_at_ammrl.org
> Subject: VT-connector

Dear Varian users,

We have a probe of our Inova 500 where the VT- connector on the probe is damaged
we like to replace the connector does any one know a supplier of these connectors.


With best regards / met vriendelijke groeten

Jan Meine Ernsting

************************************
* Ing. J.M. Ernsting
* University of Amsterdam
* Faculty of Science
*Institute of Molecular Chemistry
* NMR Department
* Nw. Achtergracht 166
* 1018 WV AMSTERDAM
* The Netherlands
*
* phone: +31.20.525 6441
* fax: +31.20.525 6456
************************************
Received on Mon Aug 30 2004 - 09:07:35 MST

This archive was generated by hypermail 2.4.0 : Thu Jun 08 2023 - 18:36:24 MST