Email Archives for November, 2004 by thread
52 messages
:
Starting
Tue Nov 02 2004 - 09:59:00 MST,
Ending
Tue Nov 30 2004 - 13:00:46 MST
This period
:
Most recent messages
sort by
: [ thread ] [
author
] [
date
] [
subject
] [
attachment
]
Nearby
: [
Other mail archives
]
Successful Restoration of our Bruker WM300 (Wide Bore) NMR Spectrometer
NMR
(Sun Oct 31 2004 - 09:36:11 MST)
printer problem
Donald Linn
(Fri Oct 29 2004 - 09:59:15 MST)
Experiences of archiving data on CDs - hopefully the last word
Phil Dennison
(Fri Oct 29 2004 - 13:49:19 MST)
spinning problem with a Bruker wide bore system
Wycoff, Wei G.
(Tue Nov 02 2004 - 15:02:52 MST)
15N relaxation agent
Philip Pfeffer
(Wed Nov 03 2004 - 08:20:49 MST)
He Purity
Brian Myers
(Wed Nov 03 2004 - 10:12:37 MST)
NOESY cross peak asymmetry
charlie dickinson
(Wed Nov 03 2004 - 09:56:01 MST)
Summary Liquid He Purity
Brian Myers
(Wed Nov 03 2004 - 16:08:13 MST)
Old Time 5 1/4'" Floppys
Gary Juneau
(Thu Nov 04 2004 - 08:56:55 MST)
Do you know if the following printer will work?
Hoeglund, Adrienne
(Thu Nov 04 2004 - 13:00:24 MST)
Free stuff
Jens Duus
(Thu Nov 04 2004 - 05:19:16 MST)
137Ba NMR
Hsin Wang
(Wed Nov 03 2004 - 13:38:09 MST)
Re: spinning problem with a Bruker wide bore system__summary
Wycoff, Wei G.
(Thu Nov 04 2004 - 11:10:20 MST)
Invitation to France and Spain, c/ba
IPSI-2005 France and Spain
(Sat Nov 06 2004 - 07:04:21 MST)
RE: 137Ba NMR (Summary)
Hsin Wang
(Sun Nov 07 2004 - 09:29:29 MST)
spectrometer per manager statistic??
Yael Balazs
(Sun Nov 07 2004 - 00:53:22 MST)
LN2 refill during holidays
Jerry Hu
(Mon Nov 08 2004 - 12:19:54 MST)
Job posting
Christopher L. Kojiro
(Mon Nov 08 2004 - 09:37:12 MST)
Boron-11 -1H correlation
charlie dickinson
(Mon Nov 08 2004 - 09:52:27 MST)
Re: Boron-11 -1H correlation
Craig Grimmer
(Tue Nov 09 2004 - 23:31:23 MST)
"Inactive" status message
Carlos R. Pacheco
(Tue Nov 09 2004 - 15:50:09 MST)
Addtional info to "Inactive" status message
Carlos R. Pacheco
(Wed Nov 10 2004 - 07:02:39 MST)
NMR facility position
Philip Pfeffer
(Tue Nov 09 2004 - 12:40:00 MST)
ATM accessory for Varian probes
Jaroslav Zajicek
(Wed Nov 10 2004 - 07:00:56 MST)
Summary: lineshape with broad base
Sandra Chapman
(Tue Nov 09 2004 - 18:25:26 MST)
job opennings
Daniel Raftery
(Wed Nov 10 2004 - 09:24:49 MST)
Will this printer work - Summary
Hoeglund, Adrienne
(Wed Nov 10 2004 - 13:20:01 MST)
Summary: "Inactive" Status message
Carlos R. Pacheco
(Wed Nov 10 2004 - 17:29:47 MST)
Help Shimming a Bruker AC80
PMARTINO
(Wed Nov 10 2004 - 11:49:28 MST)
NMR & fMRI in the same room
Robert Peterson
(Thu Nov 11 2004 - 13:53:16 MST)
BIRD 4381 Power meter
M.S.Moni
(Fri Nov 12 2004 - 00:55:17 MST)
Re: BIRD 4381 Power meter
Alan Olson
(Wed Nov 17 2004 - 07:54:31 MST)
RE: BIRD 4381 Power meter
Robert Harker
(Thu Nov 18 2004 - 08:17:05 MST)
AMMRL: NMR Position at Amgen
Rich Shoemaker
(Fri Nov 12 2004 - 14:05:46 MST)
2004 NMR salaries
William C. Stevens
(Fri Nov 12 2004 - 10:53:48 MST)
2004 salary survey
William C. Stevens
(Mon Nov 15 2004 - 09:35:36 MST)
Varian VT Probe Connector
Michael.Bernstein_at_astrazeneca.com
(Tue Nov 16 2004 - 04:40:48 MST)
Chemagnetics CMX-II and FTS chiller?
Margaret A. Eastman
(Tue Nov 16 2004 - 16:30:34 MST)
High He blowoff after system move by MR Resources
Lawrence Byrnes
(Tue Nov 16 2004 - 11:42:46 MST)
NMR & fMRI in the same room
Robert Peterson
(Thu Nov 18 2004 - 16:58:23 MST)
Buy/donate Solids Probe?
Lew Cary
(Thu Nov 18 2004 - 11:12:07 MST)
Varian Shim Driver Board
Alan Ronemus
(Fri Nov 19 2004 - 12:58:51 MST)
SUMMARY: MAS air-tight rotors, ampoules, and end-caps
Yael Balazs
(Mon Nov 22 2004 - 06:49:53 MST)
trouble with sample spinning on Bruker ARX300
Brian Breczinski
(Mon Nov 29 2004 - 09:28:50 MST)
RE: trouble with sample spinning on Bruker ARX300
Woodrow Conover II
(Mon Nov 29 2004 - 10:13:54 MST)
SpinWorks 2.4
Kirk Marat
(Thu Nov 25 2004 - 09:04:59 MST)
Varian VT Connector - Summary
Michael.Bernstein_at_astrazeneca.com
(Mon Nov 29 2004 - 06:35:22 MST)
AMMRL at ENC
Karen Ann Smith
(Mon Nov 29 2004 - 08:41:04 MST)
LN2 boiloff as spin/eject gas?
Alan Brown
(Mon Nov 29 2004 - 15:33:33 MST)
RE: LN2 boiloff as spin/eject gas?
Curran, Sean
(Tue Nov 30 2004 - 06:11:49 MST)
Proximity of Hand Tools to a 400 Unshielded Magnet
Edward E. Waali
(Tue Nov 30 2004 - 08:53:13 MST)
Converting data- help
Kimberly A Yach
(Tue Nov 30 2004 - 09:42:03 MST)
Last message date
:
Tue Nov 30 2004 - 13:00:46 MST
Archived on
: Thu Jun 08 2023 - 19:37:31 MST
52 messages
sort by
: [ thread ] [
author
] [
date
] [
subject
] [
attachment
]
Nearby
: [
Other mail archives
]
This archive was generated by
hypermail 2.4.0
: Thu Jun 08 2023 - 19:37:31 MST