AMMRL: SOP for "quenching" an NMR?
Ryan McKay
(Fri Jul 31 2015 - 12:20:56 MST)
AMMRL: Varian RF brick repairs.
Joseph Dumais
(Tue Aug 04 2015 - 10:06:09 MST)
AMMRL: Varian RF brick repairs....
rolf tschudin
(Tue Aug 04 2015 - 13:39:55 MST)
Re: AMMRL: Varian RF brick repairs....
Spin-Doc
(Wed Aug 05 2015 - 11:00:30 MST)
AMMRL: NMR Centre manager at University of Guelph
Valerie Robertson
(Wed Aug 05 2015 - 13:38:24 MST)
AMMRL: 3mm sample turbine for INOVA RT probe
Tara Sprules
(Fri Aug 07 2015 - 08:00:13 MST)
Re: AMMRL: 3mm sample turbine for INOVA RT probe
Knut Mehr
(Fri Aug 07 2015 - 13:18:43 MST)
AMMRL: Sudden change is 1H Tune windows - No 1H Signal
Kenneth Knott
(Fri Aug 07 2015 - 09:24:14 MST)
AMMRL: Sudden change is 1H Tune windows - No 1H Signal [Solved]
Kenneth Knott
(Fri Aug 07 2015 - 12:13:24 MST)
Re: AMMRL: Sudden change is 1H Tune windows - No 1H Signal [Solved]
Eugenio Alvarado
(Mon Aug 10 2015 - 11:51:22 MST)
RE: AMMRL: Sudden change is 1H Tune windows - No 1H Signal [Solved]
Hamish Grant
(Mon Aug 10 2015 - 20:39:24 MST)
RE: AMMRL: Sudden change is 1H Tune windows - No 1H Signal [Solved]
Feng Lin
(Tue Aug 11 2015 - 13:40:19 MST)
AMMRL:3mm turbine
Tara Sprules
(Fri Aug 07 2015 - 14:06:45 MST)
AMMRL: SOP for "quenching" an NMR - part 2
Ryan McKay
(Tue Aug 11 2015 - 13:35:35 MST)
AMMRL: Varian auto lock feature (VNMR)
Jacobsen, Neil E - (neil)
(Tue Aug 11 2015 - 17:09:42 MST)
AMMRL: MSR board on Inova probably dead
Tara Sprules
(Mon Aug 17 2015 - 10:03:25 MST)
AMMRL: DNA Data set needed
Nimmo, Susan L.
(Mon Aug 17 2015 - 12:57:33 MST)
AMMRL: PO Waterlogsy pulse sequence
Heffron, Gregory J.
(Wed Aug 19 2015 - 04:59:38 MST)
AMMRL: NMR facility funding in Canada
Kirk Marat
(Mon Aug 17 2015 - 13:33:22 MST)
AMMRL: removing FM radio station noise from a 77Se spectrum
Monika Ivancic
(Mon Aug 17 2015 - 13:38:09 MST)
Re: AMMRL: removing FM radio station noise from a 77Se spectrum
Ulrike Werner-Zwanziger
(Tue Aug 18 2015 - 17:23:15 MST)
AMMRL: solid-state 19F NMR probe needed
Ulrike Werner-Zwanziger
(Mon Aug 17 2015 - 17:11:38 MST)
AMMRL: rolling basline on 31P solid state NMR spectra
Kirk, Megan (MM)
(Tue Aug 18 2015 - 07:38:01 MST)
Re: AMMRL: rolling basline on 31P solid state NMR spectra
David Rice
(Tue Aug 18 2015 - 11:53:08 MST)
Re: AMMRL: rolling basline on 31P solid state NMR spectra
Bill Stevens
(Wed Aug 19 2015 - 12:05:18 MST)
AMMRL: Possible surplus of Bruker BACS-120 autosampler
Dan Bearden
(Wed Aug 19 2015 - 08:05:59 MST)
AMMRL: Oil-Free Air Compressor Question
Margaret Eastman
(Wed Aug 19 2015 - 17:02:37 MST)
AMMRL: Varian E-stick available
Hirschinger, Jerry D
(Thu Aug 20 2015 - 13:28:12 MST)
AMMRL: anti-vibration legs
Virginia Miner
(Fri Aug 21 2015 - 11:52:19 MST)
AMMRL: Career Opportunities: PostDoc Research Scientist - NMR Spectroscopy @ Colgate Palmolive Company
Donghui Wu
(Tue Aug 25 2015 - 05:41:07 MST)
AMMRL: Support for Solid-State NMR -- Update from Revolution and Phoenix NMR
Richard Shoemaker
(Wed Aug 26 2015 - 09:20:17 MST)
Re: AMMRL: Support for Solid-State NMR -- Update from Revolution and Phoenix NMR
Spin-Doc
(Wed Aug 26 2015 - 15:23:04 MST)
AMMRL: Bruker SampleXpress malfunctioning
Akien, Geoffrey
(Wed Aug 26 2015 - 09:58:10 MST)
AMMRL: Summary of Oil-Free Air Compressor Question
Margaret Eastman
(Wed Aug 26 2015 - 12:08:33 MST)
AMMRL: 300 MHz probe wanted
Eric Sorte
(Wed Aug 26 2015 - 13:56:20 MST)
AMMRL: Changing main field
Kirk Manfredi
(Wed Aug 26 2015 - 14:42:46 MST)
Re: AMMRL: Changing main field
Knut Mehr
(Thu Aug 27 2015 - 13:26:28 MST)
Re: AMMRL: Changing main field
Ronald Crouch
(Fri Aug 28 2015 - 21:33:40 MST)
Re: AMMRL: Changing main field
stolowich_at_louisville.edu
(Sat Aug 29 2015 - 15:02:55 MST)
AMMRL: Reapir of watch that has been too close to the magnet
Kirk, Megan (MM)
(Thu Aug 27 2015 - 04:39:57 MST)
AMMRL: Locking and Shimming Peculiarities
don.eldred_at_dowcorning.com
(Thu Aug 27 2015 - 05:40:44 MST)
AMMRL: Career Opportunity: Experienced NMR Scientist/Spectroscopist @ Honeywell
John M Jungk
(Thu Aug 27 2015 - 14:10:26 MST)
AMMRL: Prodigy Probe Posting Summary
Eberle Bill USGR
(Fri Aug 28 2015 - 10:11:29 MST)
AMMRL: heat exchanger for the Nitrogen exhaust ports on an NMR magnet
yong-wah kim
(Fri Aug 28 2015 - 12:59:50 MST)
AMMRL: Unshielded Oxford 600 magnet searching new home
Spin-Doc
(Mon Aug 31 2015 - 03:19:24 MST)
Last message date
:
Mon Aug 31 2015 - 00:19:31 MST
Archived on
: Mon Jun 19 2023 - 16:29:32 MST
45 messages
sort by
: [ thread ] [
author
] [
date
] [
subject
] [
attachment
]
Nearby
: [
Other mail archives
]
This archive was generated by
hypermail 2.4.0
: Mon Jun 19 2023 - 16:29:32 MST